外观
原型库(proto)
原文: https://finproducts.atlassian.net/wiki/spaces/JIDD3/pages/34793587217/FIN+5.3.1+proto 中文整理基于 FIN 5.3.1
导读: 本页为原型(proto)定义参考。
以下为 API 参考,保留英文以便对照源码;目录已列出(英文标题便于检索);概述已尽量中译。
目录(导读)
概述(中译)
空气二氧化碳浓度传感器点
API 正文(英文)
proto
air co2 concentration sp point
implements
| air | The mixture of gases which surrounds the earth |
| co2 | Carbon dioxide (CO₂) |
| co2-concentration | Concentration of carbon dioxide (CO₂) in the air |
| concentration | Abundance of substance in the total volume of a mixture |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
proto
air dewPoint sensor point
implements
| air | The mixture of gases which surrounds the earth |
| dewPoint | Dew point temperature at which water vapor will form dew |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
air dewPoint sp point
implements
| air | The mixture of gases which surrounds the earth |
| dewPoint | Dew point temperature at which water vapor will form dew |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
proto
air enthalpy sensor point
implements
| air | The mixture of gases which surrounds the earth |
| enthalpy | Total heat content of a system |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
air enthalpy sp point
implements
| air | The mixture of gases which surrounds the earth |
| enthalpy | Total heat content of a system |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
proto
air flow sensor point
implements
| air | The mixture of gases which surrounds the earth |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
air flow sp point
implements
| air | The mixture of gases which surrounds the earth |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
proto
air humidity sensor point
implements
| air | The mixture of gases which surrounds the earth |
| humidity | Percent relative humidity |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
air humidity sp point
implements
| air | The mixture of gases which surrounds the earth |
| humidity | Percent relative humidity |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
proto
air pressure sensor point
implements
| air | The mixture of gases which surrounds the earth |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| sensor | Point is a sensor, input, AI/BI |
proto
air pressure sp point
implements
| air | The mixture of gases which surrounds the earth |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
proto
air temp sensor point
implements
| air | The mixture of gases which surrounds the earth |
| air-temp | Dry bulb temperature |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| temp | Temperature - measure of hot and cold |
proto
air temp sp point
implements
| air | The mixture of gases which surrounds the earth |
| air-temp | Dry bulb temperature |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| temp | Temperature - measure of hot and cold |
proto
air velocity sensor point
implements
| air | The mixture of gases which surrounds the earth |
| air-velocity | Rate of air movement as distance over time |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| velocity | Speed in a given direction |
proto
air velocity sp point
implements
| air | The mixture of gases which surrounds the earth |
| air-velocity | Rate of air movement as distance over time |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| velocity | Speed in a given direction |
proto
alarm sensor point
implements
| alarm | Notification of a condition which requires attention |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
avg ac elec current angle sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| angle | Measurement of the relative difference in direction between two vectors or phasors |
| avg | Average |
| current | Movement of fluid or electricity |
| current-angle | AC current phase angle |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-current | Electrical current |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
avg ac elec current imbalance sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| current | Movement of fluid or electricity |
| current-imbalance | AC current phase imbalance |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-current | Electrical current |
| imbalance | Lacking balance |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
avg ac elec current magnitude sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| current | Movement of fluid or electricity |
| current-magnitude | Root-mean-square (RMS) magnitude of AC electrical current |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-current | Electrical current |
| magnitude | Size or extent |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
avg ac elec current thd sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| current | Movement of fluid or electricity |
| current-thd | Total harmonic distortion (THD) of AC current |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-current | Electrical current |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| thd | Total harmonic distortion |
proto
avg ac elec pf sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| elec | Associated with electricity or with electrical force, power, or energy |
| pf | Electric power factor |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
proto
avg ac elec volt angle sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| angle | Measurement of the relative difference in direction between two vectors or phasors |
| avg | Average |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-volt | Electrical voltage, potential difference |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| volt | Electrical potential difference or electromotive force |
| volt-angle | AC voltage phase angle |
proto
avg ac elec volt imbalance sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-volt | Electrical voltage, potential difference |
| imbalance | Lacking balance |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| volt | Electrical potential difference or electromotive force |
| volt-imbalance | AC voltage phase imbalance |
proto
avg ac elec volt magnitude sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-volt | Electrical voltage, potential difference |
| magnitude | Size or extent |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| volt | Electrical potential difference or electromotive force |
| volt-magnitude | Root-mean-square (RMS) magnitude of AC electrical voltage |
proto
avg ac elec volt thd sensor point
implements
| ac | Relating to alternating current (AC) electricity |
| ac-elec | Alternating current electricity |
| avg | Average |
| elec | Associated with electricity or with electrical force, power, or energy |
| elec-volt | Electrical voltage, potential difference |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| thd | Total harmonic distortion |
| volt | Electrical potential difference or electromotive force |
| volt-thd | Total harmonic distortion (THD) of AC voltage |
proto
bypass damper cmd point
implements
| bypass | Pipe used to bypass an equipment |
| cmd | Point is a command, actuator, AO/BO |
| damper | Damper equipment or control point |
| point | Data point such as a sensor or actuator |
proto
chilled water bypass equip
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| equip | Equipment asset |
| water | Water in its liquid form |
children
| equip | |
| point | |
| point | |
proto
chilled water bypass flow sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water bypass flow sp point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| water | Water in its liquid form |
proto
chilled water bypass pipe equip
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| equip | Equipment asset |
| pipe | Conduit used to convey a fluid |
| water | Water in its liquid form |
children
proto
chilled water bypass point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| water | Water in its liquid form |
proto
chilled water bypass pressure sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water bypass pressure sp point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| water | Water in its liquid form |
proto
chilled water bypass pump alarm sensor point
implements
| alarm | Notification of a condition which requires attention |
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water bypass pump enable cmd point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| enable | Secondary on/off point of an equip especially used with a vfd |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| water | Water in its liquid form |
proto
chilled water bypass pump enable sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| enable | Secondary on/off point of an equip especially used with a vfd |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water bypass pump equip
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| equip | Equipment asset |
| pump | Pump equipment or control point |
| water | Water in its liquid form |
children
| equip | |
| point | |
| point | |
proto
chilled water bypass pump motor equip
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| equip | Equipment asset |
| motor | Equipment that converts electrical energy into mechanical energy |
| pump | Pump equipment or control point |
| pump-motor | Motor used with a pump to move fluid |
| water | Water in its liquid form |
children
proto
chilled water bypass pump point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| water | Water in its liquid form |
proto
chilled water bypass pump run cmd point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| run | Primary on/off point of an equip especially used with a vfd |
| water | Water in its liquid form |
proto
chilled water bypass pump run sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| run | Primary on/off point of an equip especially used with a vfd |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water bypass pump vfd freq cmd point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| freq | Occurrences per unit time |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| vfd | Variable-frequency drive |
| vfd-freq | VFD frequency measured in "Hz" |
| water | Water in its liquid form |
proto
chilled water bypass pump vfd freq sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| freq | Occurrences per unit time |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| vfd | Variable-frequency drive |
| vfd-freq | VFD frequency measured in "Hz" |
| water | Water in its liquid form |
proto
chilled water bypass pump vfd speed cmd point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| speed | Distance per unit time |
| vfd | Variable-frequency drive |
| vfd-speed | VFD speed measured in "%" |
| water | Water in its liquid form |
proto
chilled water bypass pump vfd speed sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| speed | Distance per unit time |
| vfd | Variable-frequency drive |
| vfd-speed | VFD speed measured in "%" |
| water | Water in its liquid form |
proto
chilled water bypass temp sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| temp | Temperature - measure of hot and cold |
| water | Water in its liquid form |
proto
chilled water bypass temp sp point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| temp | Temperature - measure of hot and cold |
| water | Water in its liquid form |
proto
chilled water bypass valve actuator equip
implements
| actuator | Equipment to move or control a mechanism |
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| equip | Equipment asset |
| valve | Valve equipment or control point |
| valve-actuator | Actuator to regulate the flow of fluid |
| water | Water in its liquid form |
children
proto
chilled water bypass valve cmd point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| point | Data point such as a sensor or actuator |
| valve | Valve equipment or control point |
| water | Water in its liquid form |
proto
chilled water bypass valve sensor point
implements
| bypass | Pipe used to bypass an equipment |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| valve | Valve equipment or control point |
| water | Water in its liquid form |
proto
chilled water cool valve cmd point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| cool | Associted with low temperature or cooling processes |
| cool-water | Relatively cool water without active chilling |
| point | Data point such as a sensor or actuator |
| valve | Valve equipment or control point |
| water | Water in its liquid form |
proto
chilled water delta flow point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| delta | Differential of fluid between entering and leaving sensors |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| water | Water in its liquid form |
proto
chilled water delta flow sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| delta | Differential of fluid between entering and leaving sensors |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water delta pressure point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| delta | Differential of fluid between entering and leaving sensors |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| water | Water in its liquid form |
proto
chilled water delta temp point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| delta | Differential of fluid between entering and leaving sensors |
| point | Data point such as a sensor or actuator |
| temp | Temperature - measure of hot and cold |
| water | Water in its liquid form |
proto
chilled water delta temp sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| delta | Differential of fluid between entering and leaving sensors |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| temp | Temperature - measure of hot and cold |
| water | Water in its liquid form |
proto
chilled water entering equip
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| equip | Equipment asset |
| water | Water in its liquid form |
children
| equip | |
| point | |
| point | |
proto
chilled water entering flow sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water entering flow sp point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| flow | Measure of volumetric flow of fluid |
| point | Data point such as a sensor or actuator |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| water | Water in its liquid form |
proto
chilled water entering pipe equip
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| equip | Equipment asset |
| pipe | Conduit used to convey a fluid |
| water | Water in its liquid form |
children
proto
chilled water entering point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| water | Water in its liquid form |
proto
chilled water entering pressure sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water entering pressure sp point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pressure | Measure of force applied |
| sp | Point is a setpoint, soft point, internal control variable, schedule |
| water | Water in its liquid form |
proto
chilled water entering pump alarm sensor point
implements
| alarm | Notification of a condition which requires attention |
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water entering pump enable cmd point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| enable | Secondary on/off point of an equip especially used with a vfd |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| water | Water in its liquid form |
proto
chilled water entering pump enable sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| enable | Secondary on/off point of an equip especially used with a vfd |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water entering pump equip
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| equip | Equipment asset |
| pump | Pump equipment or control point |
| water | Water in its liquid form |
children
| equip | |
| point | |
| point | |
proto
chilled water entering pump motor equip
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| equip | Equipment asset |
| motor | Equipment that converts electrical energy into mechanical energy |
| pump | Pump equipment or control point |
| pump-motor | Motor used with a pump to move fluid |
| water | Water in its liquid form |
children
proto
chilled water entering pump point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| water | Water in its liquid form |
proto
chilled water entering pump run cmd point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| run | Primary on/off point of an equip especially used with a vfd |
| water | Water in its liquid form |
proto
chilled water entering pump run sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| run | Primary on/off point of an equip especially used with a vfd |
| sensor | Point is a sensor, input, AI/BI |
| water | Water in its liquid form |
proto
chilled water entering pump vfd freq cmd point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| cmd | Point is a command, actuator, AO/BO |
| entering | Pipe conveys fluid into an equipment |
| freq | Occurrences per unit time |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| vfd | Variable-frequency drive |
| vfd-freq | VFD frequency measured in "Hz" |
| water | Water in its liquid form |
proto
chilled water entering pump vfd freq sensor point
implements
| chilled | Substance is cooled using cooling process |
| chilled-water | Water cooled for use in HVAC and industrial processes |
| entering | Pipe conveys fluid into an equipment |
| freq | Occurrences per unit time |
| point | Data point such as a sensor or actuator |
| pump | Pump equipment or control point |
| sensor | Point is a sensor, input, AI/BI |
| vfd | Variable-frequency drive |
| vfd-freq | VFD frequency measured in "Hz" |
| water | Water in its liquid form |